The Delta VFD-EL Series is a multifunction micro AC drive developed for compact motor-control applications. It combines a built-in keypad with high-precision current detection, overload protection and practical installation features for small machinery, pumps, fans and conveyor systems.
For process control, the VFD-EL provides built-in PID feedback control and a three-point adjustable V/f curve. Its output-frequency range of 0.1 to 600 Hz gives system designers flexibility when matching drive operation to the motor and driven equipment.
The series includes an RS-485 communication interface through an RJ-45 connector and supports the Modbus protocol. Delta also lists optional communication modules for PROFIBUS, DeviceNet, LonWorks and CANopen. Additional integration features include easy DC-bus sharing for side-by-side installation and an RFI switch for IT mains.
DriveTechno supplies Delta VFD-EL drives and provides installation, commissioning, parameter setting, troubleshooting, repair, preventive maintenance and control-panel engineering services for industrial customers in Dubai and across the UAE.
- Compact multifunction drive:Combines essential motor-control and system-integration functions in a micro-drive format.
- Built-in PID control:Supports feedback-based control for applications such as small pumps and fans.
- Adjustable V/f curve:A three-point adjustable V/f curve enables application-specific voltage and frequency settings.
- Wide output-frequency range:Delta specifies an adjustable output frequency from 0.1 to 600 Hz.
- Integrated Modbus communication:RS-485 through an RJ-45 connector supports the Modbus protocol.
- Optional fieldbus connectivity:Communication modules are listed for PROFIBUS, DeviceNet, LonWorks and CANopen.
- Installation flexibility:DC-bus sharing is designed to support side-by-side drive installation when the common-bus system is correctly engineered.
- Built-in operational features:High-precision current detection, overload protection and an integrated keypad support everyday operation.
Built-in PID Feedback Control
The integrated PID function enables the drive to respond to a feedback signal and regulate the controlled process. Sensor type, signal scaling, PID parameters and protection settings must be configured for the actual application.
Three-Point Adjustable V/f Curve
The VFD-EL provides a three-point adjustable V/f curve for adapting the voltage-frequency relationship to the motor and load. Settings must remain within the motor and machine operating limits.
Output Frequency
Delta specifies an output-frequency range of 0.1 to 600 Hz. The permitted operating frequency must also comply with the motor, driven equipment and applicable safety requirements.
RS-485 Modbus Communication
The drive uses an RS-485 communication interface with an RJ-45 connector and supports the Modbus protocol, allowing integration with compatible controllers and automation systems.
Optional Communication Modules
Delta lists optional communication modules for PROFIBUS, DeviceNet, LonWorks and CANopen. Module availability and compatibility must be verified for the selected drive and control network.
Built-in EMI Filter
Delta specifies a built-in EMI filter for 230 V single-phase and 460 V three-phase models. The exact model code, filter arrangement and installation requirements must be confirmed before selection.
RFI Switch for IT Mains
The VFD-EL includes an RFI switch for IT mains. Earthing arrangement, EMC requirements and the permitted switch position must be verified for the power-distribution system.
DC-Bus Sharing
The series supports easy DC-bus sharing for side-by-side installation. Common-bus wiring, protective devices, drive compatibility and energy flow must be engineered for the actual system.
Current Detection, Keypad and Protection
Delta lists high-precision current detection, overload protection, a built-in keypad and complete protection functions among the VFD-EL features. Drive parameters and any required external protection devices must be selected according to the motor and application.
Typical Applications
- Small pumps
- Small fans
- Blowing machines
- Conveyor belts
- Simple processing equipment