MV VFD and Power Cell Repair

Fault Diagnosis

Power Cell Assessment 

Return-to-Service Testing
Diagnose the Complete MV VFD
A cell fault message is a starting point, not the whole diagnosis. We review event history, protection trips, control power, cooling, phase-shifting transformer interfaces, communications, bypass status and the operating duty.
Key Areas of MV VFD Diagnosis
Event history and protection trips
Review fault records, trip conditions and operating duty.
Power cell and control power
Assess cell condition, auxiliary supplies and driver circuits.
Cooling and transformer interfaces
Check cooling systems and phase-shifting transformer interfaces.
Communications and bypass status
Review fiber links, wiring, sensing and system communication.
Power Cell Repair and Replacement
A repair proposal is based on inspection, component availability and testability. Where repair is not suitable, we can investigate a compatible replacement or spare cell strategy with the client.
Technical Selection & Engineering
- Power cell identification and platform compatibility
- Semiconductor, rectifier and DC link component condition
- Gate driver, auxiliary power and control card checks
- Cooling, connections and fiber link condition
- Component availability and repair feasibility
- Compatible replacement or spare cell strategy
- Workshop and site testing limits and acceptance criteria
Project Scope and Evidence
Testing and Return-to-Service
Testing and recommissioning are planned around the condition of the cell, available facilities and the wider MV VFD installation. Site operating verification is considered in the context of the complete VFD, motor and load.
Frequently Asked Questions
Do you repair individual MV VFD power cells?
Often yes, if its capacity and connection point are selected for the combined operating profile. Duty and standby combinations should be included in the study.
Can you work on a VFD from another supplier?
No. Active filters suit varying loads, while passive filters can be attractive for stable and predictable applications. Both should be compared for the actual operating requirements.
What information helps an urgent assessment?
It depends on the reactive power requirement and the selected AHF functions and capacity. Existing capacitor banks and detuned reactors should be reviewed as part of the complete design.