Capacitor Bank and APFC Panels
A capacitor bank or APFC panel compensates inductive reactive power in an electrical installation. An automatic power factor correction controller connects and disconnects capacitor steps as the load changes, helping maintain the selected displacement power factor within the operating conditions of the system.
DriveTechno supports APFC panel supply, replacement and upgrade enquiries in the UAE. Selection considers measured kW and kvar, the load profile and any harmonic-producing equipment. Send your power quality data or existing capacitor bank details so compensation, switching and protection can be reviewed before the required kvar is fixed.

Reactive Power Compensation

Automatic Step Switching

Power
Capacitor Bank and APFC Panel Solutions
A capacitor bank or APFC panel compensates inductive reactive power in an electrical installation. An automatic power factor correction controller connects and disconnects capacitor steps as the load changes, helping maintain the selected displacement power factor within the operating conditions of the system.DriveTechno supports APFC panel supply, replacement and upgrade enquiries in the UAE. Selection considers measured kW and kvar, the load profile and any harmonic-producing equipment. Send your power quality data or existing capacitor bank details so compensation, switching and protection can be reviewed before the required kvar is fixed.
Typical Applications

Industrial facilities with changing inductive loads

Commercial plant rooms and utility distribution systems

Replacement of failed capacitor steps or obsolete APFC controls

Detuned bank enquiries for networks with nonlinear loads
Selecting Compensation for the Actual Load
Required compensation is calculated from the load active power and the change from existing to target displacement power factor. The step sizes and controller settings must suit the variation in load. Oversized steps can cause hunting or excessive leading compensation during light load. A fixed kvar selection should therefore be supported by load information rather than transformer rating alone.
⚙ Technical Selection Checklist
| Selection Item | Information to Confirm |
|---|---|
| Electrical network | Voltage, frequency, transformer details and available fault current |
| Load profile | Measured kW, kvar, displacement and true power factor across operating conditions |
| Compensation steps | Required kvar, step sizes, operating frequency and spare capacity |
| Harmonics | Voltage and current distortion, nonlinear load details and resonance assessment |
| Reactors and capacitors | Detuning requirement, component voltage and current duty and thermal design |
| Measurement | CT ratio, location, polarity, phase association and controller requirements |
| Installation | Switching type, ventilation, enclosure, access, alarms and documentation |
Detuned Reactors and Harmonic Exposure
Capacitors interact with the network impedance and can be exposed to harmonic current or resonance. Detuned banks use series reactors selected with the capacitors for the network duty. The reactor changes the voltage across the capacitor and the assembly thermal conditions. The correct tuning, component ratings and protection are chosen from the system assessment, not from one universal reactor percentage. Compensation capacity is stated in kvar, while the controller usually uses voltage and current feedback to determine the switching response. Confirm whether the stated target is displacement power factor or true power factor, particularly where VFDs or other nonlinear loads are significant.
Step Switching and Control Feedback
Contactor switching can suit loads that change at a manageable rate; thyristor switching may be considered for faster changes where the design requires it. Switching frequency, capacitor discharge requirements and controller delays must be coordinated. The CT must measure the intended system boundary with the correct ratio, phase and polarity so the controller responds to compensation correctly.
Power Factor and Energy Expectations
Reactive power compensation can reduce reactive current and release network capacity under suitable conditions. Any billing effect depends on the actual tariff and measured load. Capacitors do not directly remove the active energy used by a machine. Harmonic distortion also affects true power factor, so displacement power factor correction is not a substitute for a harmonic assessment.
APFC Panel Inspection and Testing
The agreed checks can include capacitor and reactor condition, protective devices, controller settings, CT association, step operation and ventilation. Commissioning should assess the power factor response across available load conditions. For an upgrade, existing harmonic measurements and the condition of reusable components help establish the appropriate scope.
Frequently Asked Questions
Can the capacitor bank be sized from the transformer kVA?
Does a detuned capacitor bank replace an active harmonic filter?
Why does the controller keep switching steps repeatedly?
Request an APFC Panel Quotation
Send the following information with your enquiry. Existing drawings, photographs and equipment data can help clarify any details that are not yet available.
System voltage, transformer and single-line diagram · Measured load kW, kvar and power factor profile · Harmonic readings and major nonlinear load details · Existing bank rating, step schedule and component photos · CT information, enclosure and environmental conditions · Required upgrades, alarms, site tests and supply scope
Email your enquiry to info@DriveTechno.ae. We will review the application and prepare a quotation against the agreed technical requirements and scope.