Delta VFD-EL-W
Direct Technical Support
- +971 50 332 7971
- info@drivetechno.ae
The Delta VFD-EL-W Series is a new-generation compact vector control drive developed for practical motor-control applications that require a simple, durable and space-efficient solution. Its design carries forward Delta’s established AC-drive technology while integrating the functions required for machinery, material handling and constant-pressure pump systems.
Standard functions include multi-step operation, torque compensation, PID control, multi-pump control, constant-pressure water supply and leakage detection. The drive can be operated from its digital panel, external terminals or Modbus communication, giving machine builders and system integrators several options for command and control.
Delta also specifies a complete built-in protection mechanism covering overcurrent, overvoltage, undervoltage, overheating, overload, overtorque and phase loss. High overload capacity of 150% rated current for one minute supports demanding operating conditions when the drive, motor and load are correctly selected.
DriveTechno supplies Delta VFD-EL-W drives and provides installation, commissioning, parameter setting, PID and pump-control configuration, troubleshooting, repair, preventive maintenance and control-panel engineering services for industrial customers in Dubai and across the UAE.
- Compact and durable design:A simple, space-efficient drive platform for machinery and pump-control applications.
- Integrated process control:Built-in PID, multi-pump control and constant-pressure water-supply functions reduce the need for separate control components in suitable applications.
- Leakage detection:The integrated leakage-detection function supports constant-pressure water systems when correctly configured.
- Flexible operating commands:The drive can be controlled from the digital panel, external terminals or Modbus communication.
- Multi-step operation:Preset operating steps support applications that require several defined speed commands.
- Torque compensation:Built-in torque compensation helps the drive respond to application load requirements.
- Two-motor capability:Delta states that one drive can support two motors connected in parallel, subject to correct combined-current sizing and motor protection.
- High overload capacity:Rated for 150% of rated current for one minute.
- Comprehensive protection:Built-in monitoring covers overcurrent, overvoltage, undervoltage, overheating, overload, overtorque and phase loss.
Multi-Step and Multi-Speed Operation
The VFD-EL-W provides multi-step and multi-speed operation for applications that require preset speed references. Speed values, acceleration and deceleration times, command priorities and interlocks must be configured for the machine.
Digital Panel, External Terminal and Modbus Control
Three control methods are listed by Delta: the drive’s digital panel, external control terminals and Modbus communication. The selected command source and frequency-reference source must be set correctly during commissioning.
Torque Compensation
The built-in torque-compensation function supports motor operation under changing load conditions. Motor data and compensation settings must be matched to the actual motor and driven equipment.
PID and Multi-Pump Control
Integrated PID and multi-pump functions allow the VFD-EL-W to regulate a process variable and coordinate suitable pump-system operation. Feedback-signal type, sensor range, PID values, sleep/wake logic and pump sequencing require application-specific engineering.
Constant-Pressure Water Supply
The drive includes a constant-pressure water-supply function for pump applications. Correct operation depends on pressure-sensor selection, signal scaling, setpoint configuration, pipework conditions and system protection.
Leakage Detection
Delta lists leakage detection among the standard VFD-EL-W functions. Detection thresholds and response settings must be commissioned according to the characteristics of the water-supply system.
Parallel Operation of Two Motors
The VFD-EL-W supports one drive operating two motors connected in parallel. The drive must be sized for the combined motor current, and each motor requires suitable individual overload protection where applicable.
Time Out Detection
Delta specifies a Time Out Detection function. Its trigger conditions, timing and fault response must be selected to match the control sequence and protection strategy.
Overload Capacity
The official product specification states an overload capacity of 150% rated current for one minute. Repeated overload duty, ambient temperature, carrier frequency and installation conditions must be considered during drive selection.
Integrated Protection Mechanism
The VFD-EL-W includes built-in protection for overcurrent, overvoltage, undervoltage, overheating, overload, overtorque and phase loss. External protective devices and correct grounding are still required according to the installation design and applicable standards.
Typical Applications
- Edge-banding machines
- Logistics conveyors
- Material-handling systems
- Constant-pressure pumps